FL10999: Metal Sales Manufacturing, LLC, Roof Deck

2026 code statusPending

FL10999-R6 is on file under the 2026 code with status “Pending FBC Approval”. Not approved for 2026 yet.

Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.

Filing record

2026 application
FL10999-R6, Pending FBC Approval (Revision) · state record
2023 code approval
FL10999-R5, Approved · state record
Submitted
Oct 3, 2026
Validated
Oct 13, 2026
Pending FBC approval
Oct 17, 2026
Approved for HVHZ
No
Impact resistant
No
Compliance method
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Quality assurance
Keystone Certifications, Inc.
Validated by
Yoosef Lavi, P.E.

Products under this number (11)

#Model / descriptionHVHZImpactDesign pressure
10999.17/8" Corrugated Panel Min. 24 ga., 32" wide coverage through fastened roof panelNoN/A+N/A/-156.4
10999.2Aluminum Magna-Loc Min. 0.032" thick, 16" wide standing seam roof panel with standard clip over open supports or deckNoN/A+N/A/-87.5
10999.3Classic Rib Min. 26 ga., 36" wide, through fastened roof panel over open 18 ga. steel supportsNoN/A+N/A/-156
10999.4Classic Rib Min. 26 ga., 36" wide, through fastened roof panel over open steel supportsNoN/A+N/A/-138.7
10999.5Classic Rib Min. 29 ga., 36" wide, through fastened panel over open wood supportsNoN/A+N/A/-128.3
10999.6Magna-Loc Min. 24 ga., 16" wide standing seam roof panel with standard clip over open supportsNoN/A+N/A/-146.7
10999.7Magna-Loc 180 Min. 24 ga., 16" wide standing seam roof panel over open supportsNoN/A+N/A/-117.7
10999.8PBR Min. 26 ga., 36" wide, through fastened panel over steel supportsNoN/A+N/A/-154.4
10999.9PBR Min. 26 ga., 36" wide, through fastened roof panel over open 18 ga. steel supportsNoN/A+N/A/-133.3
10999.10Seam-Loc 24 24 or 22 ga., max 24" wide standing seam roof panel over open supportsNoN/A+N/A/-74.1
10999.11Seam-Loc 24 with Clamps Min. 24 ga., max. 24" wide standing seam roof panel with S-5! clamps over open supportsNoN/A+N/A/-130.9

Standards cited

ASTM E1592 2017; FM 4470 2022