Home / Roofing / Englert Inc.
FL11751: Englert Inc., Metal Roofing
2026 code statusReady
FL11751-R10 is listed as Approved under code version 2026.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL11751-R10, Approved (Revision) · state record
- 2023 code approval
- FL11751-R9, Approved · state record
- Submitted
- Aug 11, 2026
- Validated
- Aug 19, 2026
- Pending FBC approval
- Aug 20, 2026
- Approved
- Oct 13, 2026
- Approved for HVHZ
- Yes
- Impact resistant
- No
- Compliance method
- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
- Quality assurance
- Keystone Certifications, Inc.
- Validated by
- Steven M. Urich, PE
Products under this number (10)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 11751.1 | 01 - Englert "Series 2000" Roof Panel - 24 Gauge Steel, 18" Width, Attached to Plywood Deck | No | No |
| 11751.2 | 02 - Englert "Series 2000" Roof Panel - 0.032" Aluminum, 18" Width, Attached to Wood Deck | No | No |
| 11751.3 | 03 - Englert "Series 2000" Roof Panel - 24 Gauge Steel, 18" Width or 14" Width, Attached to Steel Deck | No | No |
| 11751.4 | 04 - Englert "Series 2000" Roof Panel - 0.040" Aluminum, 18" Width, Attached to Wood Deck | No | No |
| 11751.5 | 05 - Englert "Series 2000" Roof Panel - 0.032" Aluminum, 18" Width, Attached to Steel Deck | No | No |
| 11751.6 | 06 - Englert "Series 2000" Roof Panel - 24 Gauge Steel, 18" Width, Attached to Plywood Deck | Yes | No |
| 11751.7 | 07 - Englert "Series 2000" Roof Panel - 0.032" Aluminum, 18" Width, Attached to Wood Deck | Yes | No |
| 11751.8 | 08 - Englert "Series 2000" Roof Panel - 24 Gauge Steel, 18" Width or 14" Width, Attached to Steel Deck | Yes | No |
| 11751.9 | 09 - Englert "Series 2000" Roof Panel - 0.040" Aluminum, 18" Width, Attached to Wood Deck | Yes | No |
| 11751.10 | 10 - Englert "Series 2000" Roof Panel - 0.032" Aluminum, 18" Width, Attached to Steel Deck | Yes | No |
Standards cited
TAS 100 2023; TAS 125 2003
Miami-Dade NOAs, same maker
Matched by company name. The state doesn't link NOAs to FL numbers.
| NOA | Description | Expires |
|---|---|---|
| 25-0829.03 | Englert Metal Man HT.Unselected / Unknown, +0/−0 psf | September 29 2030 |
Verify FL11751 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com
Other Englert Inc. numbers
- FL11351 ReadyUnderlayments
- FL11698 ReadyMetal Roofing
- FL11727 ReadyMetal Roofing
- FL11752 ReadyMetal Roofing
- FL14668 ReadyRoof Deck
- FL17024 ReadyStructural Wall
- FL17209 ReadyStructural Wall
- FL17216 ReadySoffits
- FL31655 ReadyMetal Roofing
- FL39748 ReadyMetal Roofing
- FL40562 ReadyMetal Roofing
- FL46932 ReadyMetal Roofing
Get the weekly list