FL Approval Watch
Florida product approvals: status, revisions, NOA expirations, weekly changes

Home / Windows / Fleetwood Windows and Doors

FL14904: Fleetwood Windows and Doors, Casement

2026 code statusPending

FL14904-R10 is on file under the 2026 code with status “Pending FBC Approval”. Not approved for 2026 yet.

Last checked against floridabuilding.org: Oct 20, 2026, 6:52 AM ET. See the state record.

Filing record

2026 application
FL14904-R10, Pending FBC Approval (Revision) · state record
2023 code approval
FL14904-R9, Approved · state record
Submitted
Jul 12, 2026
Validated
Sep 23, 2026
Pending FBC approval
Oct 3, 2026
Approved for HVHZ
Yes
Impact resistant
Yes
Compliance method
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Quality assurance
National Accreditation and Management Institute
Validated by
Ryan J. King, P.E.

Products under this number (15)

#Model / descriptionHVHZImpactDesign pressure
14904.1a. Series 3800-T w/ Series 350-T Thermally Broken Extruded Aluminum Vent Casement Window with "Non-Impact" Monolithic Glass (with and without Nailing Fin)NoNoN/A
14904.2b. Series 3800-T w/ Series 350-T Thermally Broken Extruded Aluminum Mulled Vent Casement Window with "Non-Impact" Monolithic Glass (with and without Nailing Fin)NoNoN/A
14904.3c. Series 3800-T w/ Series 350-T Thermally Broken Extruded Aluminum Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic Glass (with and without Nailing Fin)NoYesN/A
14904.4d. Series 3800-T w/ Series 350-T Thermally Broken Extruded Aluminum Mulled Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic Glass (with and without Nailing Fin)NoYesN/A
14904.5e. Series 3800-T w/ Series 350-T Thermally Broken Extruded Aluminum Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic Glass (with and without Nailing Fin)YesYesN/A
14904.6f. Series 3800-T w/ Series 350-T Thermally Broken Extruded Aluminum Mulled Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic Glass (with and without Nailing Fin)YesYesN/A
14904.7g. Series 3800-T w/ Series 350-T Stacked Vertical or Horizontal Mulled Thermally Broken Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic GlassYesYesN/A
14904.8h. Series 350-T Direct Mount Thermally Broken Extruded Aluminum Vent Casement Window with "Non-Impact" Monolithic GlassNoNoN/A
14904.9i. Series 350-T Direct Mount Thermally Broken Extruded Aluminum Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic GlassNoYesN/A
14904.10j. Series 350-T Direct Mount Thermally Broken Extruded Aluminum Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic GlassYesYesN/A
14904.11k. Series 3800-T w/ Series 350-T Thermally Broken Extruded Aluminum Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic Glass Utilizing "Wet Glaze" Installation (with and without Nailing Fin)NoYesN/A
14904.12l. Series 3800-T w/ Series 350-T Thermally Broken Extruded Aluminum Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic Glass Utilizing "Wet Glaze" Installation (with and without Nailing Fin)YesYesN/A
14904.13m. Series 3800-T w/ Series 350-T Stacked Vertical or Horizontal Mulled Thermally Broken Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic Glass Utilizing "Wet Glaze" Installation (with and without Nailing Fin)YesYesN/A
14904.14n. Series 350-T Direct Mount Thermally Broken Extruded Aluminum Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic Glass, Utilizing "Wet Glaze" Installation (with and without Nailing Fin)NoYesN/A
14904.15o. Series 350-T Direct Mount Thermally Broken Extruded Aluminum Vent Casement Window with Laminated Insulated Glass or Laminated Monolithic Glass, Utilizing "Wet Glaze" Installation (with and without Nailing Fin)YesYesN/A

Standards cited

AAMA/WDMA/CSA101/I.S.2/A440 2008; AAMA/WDMA/CSA101/I.S.2/A440 2017; ASTM C864 2005; ASTM E1300 2024; ASTM E1886 2005; ASTM E1886 2013; ASTM E1996 2006; ASTM E1996 2014; TAS 201, 202, 203 1994

Verify FL14904 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com

Other Fleetwood Windows and Doors numbers

  • FL14907 PendingAwning
  • FL15560 PendingSliding Exterior Door Assemblies
  • FL16925 PendingFixed
  • FL17954 PendingSwinging Exterior Door Assemblies
  • FL40320 PendingSwinging Exterior Door Assemblies

All Fleetwood Windows and Doors FL numbers

Get the weekly list