FL Approval Watch
Florida product approvals: status, revisions, NOA expirations, weekly changes

Home / Windows / Jeld-Wen

FL22281: Jeld-Wen, Fixed

2026 code statusReady

FL22281-R14 is listed as Approved under code version 2026.

Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.

Filing record

2026 application
FL22281-R14, Approved (Revision) · state record
2023 code approval
FL22281-R13, Approved · state record
Submitted
Jul 1, 2026
Validated
Jul 12, 2026
Approved
Jul 13, 2026
Approved for HVHZ
No
Impact resistant
Yes
Compliance method
Certification Mark or Listing
Validated by
Steven M. Urich, PE

Products under this number (20)

#Model / descriptionHVHZImpactDesign pressure
22281.1Premium Vinyl (V-4500) Casement Fixed Direct Set 36" x 72" Insulated Glass (1/4" PVB Laminate in -1/8" Annealed out)NoYes+50/-55
22281.2Premium Vinyl (V-4500) Casement Fixed Direct Set 3 Panel (OOO) 108" x 72" Insulated Glass (1/4" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.3Premium Vinyl (V-4500) Casement Fixed Insash 36" x 72" Insulated Glass (1/4" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.4Premium Vinyl (V-4500) Casement Fixed Insash 3 Panel (OOO) 108" x 72" Insulated Glass (1/4" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.5Premium Vinyl (V-4500) Fixed 48" x 84" Insulated Glass (1/4" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.6Premium Vinyl (V-4500) Fixed 60" x 60" Insulated Glass (1/4" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.7Premium Vinyl (V-4500) Fixed w/ Track Filler 48" x 84" Insulated Glass (1/4" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.8Premium Vinyl (V-4500) Fixed w/ Track Filler 60" x 60" Insulated Glass (1/4" PVB Laminate in 1/8" Annealed out)NoYes+50/-55
22281.9Premium Vinyl (V-4500) Fixed w/ Track Filler 3 Panel (OOO) 108" x 72" Insulated Glass (1/4" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.10Premium Vinyl (V-4500) Fixed 48" x 84" Insulated Glass (5/16" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.11Premium Vinyl (V-4500) Fixed 60" x 60" Insulated Glass (5/16" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.12Premium Vinyl (V-4500) Fixed w/ Track Filler 48" x 84" Insulated Glass (5/16" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.13Premium Vinyl (V-4500) Fixed w/ Track Filler 60" x 60" Insulated Glass (5/16" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.14Premium Vinyl (V-4500) Fixed w/ Track Filler 72" x 72" Insulated Glass (5/16" SGP Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.15Premium Vinyl (V-4500) Fixed w/ Track Filler 3 Panel (OOO) 108" x 72" Insulated Glass (5/16" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.16Premium Vinyl (V-4500) Casement Fixed Insash 36" x 72" Insulated Glass (5/16" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.17Premium Vinyl (V-4500) Casement Fixed Insash 60" x 60" Insulated Glass (5/16" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.18Premium Vinyl (V-4500) Casement Fixed Insash 3 Panel (OOO) 108" x 72" Insulated Glass (5/16" PVB Laminate in - 1/8" Annealed out)NoYes+50/-55
22281.19Premium Vinyl (V-4500) Sidelite (O) 36" x 80" Insulated Glass (5/16" PVB Laminate in - 5/16" Annealed out)NoYes+50/-55
22281.20Premium Vinyl (V-4500) Transom (O) 72" x 36" Insulated Glass (5/16" PVB Laminate in - 5/16" Annealed out)NoYes+50/-55

Standards cited

AAMA/WDMA/CSA 101/I.S.2/A440 2017; AAMA/WDMA/CSA 101/I.S.2/A440 2011; ASTM E1886 2013; ASTM E1996 2014

Verify FL22281 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com

Other Jeld-Wen numbers

All Jeld-Wen FL numbers

Get the weekly list