FL Approval Watch
Florida product approvals: status, revisions, NOA expirations, weekly changes

Home / Exterior Doors / ASSA ABLOY ACCENTRA

FL3063: ASSA ABLOY ACCENTRA, Exterior Door Components

2026 code statusPending

FL3063-R17 is on file under the 2026 code with status “Applied For”. Not approved for 2026 yet.

Last checked against floridabuilding.org: Oct 20, 2026, 6:52 AM ET. See the state record.

Filing record

2026 application
FL3063-R17, Applied For (Revision) · state record
2023 code approval
FL3063-R16, Approved · state record
Submitted
Sep 10, 2026
Approved for HVHZ
Yes
Impact resistant
Yes
Compliance method
Certification Mark or Listing
Validated by
Troy Bishop, P.E.

Products under this number (20)

#Model / descriptionHVHZImpactDesign pressure
3063.12100(F)WS Exit Device Panic or Fire Rated HardwareYesYes+50/-50
3063.24600LN Series Cylindrical Lockset Latching HardwareYesYes+50/-50
3063.34700LN Series Cylindrical Lockset Latching HardwareYesYes+50/-50
3063.44800LN Interconnected Lock Latching HardwareYesYes+70/-70
3063.55300/5300LN Series Cylindrical Lockset with or without Securitron UNL Unlatch Electromechanical Strike Latching HardwareYesYes+60/-60
3063.65400/5400LN Series Cylindrical Lockset with 3600 Series Deadbolt or D100 Series Deadbolt Latching HardwareYesYes+70/-70
3063.75400/5400LN Series Cylindrical Lockset with or without Securitron UNL Unlatch Electromechanical Strike Latching HardwareYesYes+60/-60
3063.86150EDWS, 6150ED(F)WS Rim Type Device, 6000 SeriesYesYes+70/-70
3063.96170EDWS, 6170ED(F)WS Surface Vertical Rod Type Exit Device, 6000 SeriesYesYes+70/-70
3063.106250MEDWS, 6250MED(F)WS Rim Type Exit Device, 6000 SeriesYesYes+70/-70
3063.117150(F)WS/7250(F)WS Squarebolt Exit Device with or without 500F, 600F Series Trims, or prefixed "Sym" (Symphony Trim) Panic or Fire Rated HardwareYesYes+70/-70
3063.127150(F)WS/7250(F)WS Squarebolt Exit Device with or without 500F, 600F Series Trims, or prefixed "Sym" (Symphony Trim) Panic or Fire Rated HardwareYesYes+115/-115
3063.137150(F)WS/7250(F)WS Squarebolt Exit Device with or without 500F, 600F Series Trims, or prefixed "Sym" (Symphony Trim) Panic or Fire Rated HardwareYesYes+60/-60
3063.147170(F)WS Surface Vertical Rod Exit Device with or without 500F, 600F Series Trims, or prefixed "Sym" (Symphony Trim) Panic or Fire Rated HardwareYesYes+70/-70
3063.157380F Multi-Point Lock Latching HardwareYesYes+150/-150
3063.1682 Series Interconnect Lockset Latching HardwareYesYes+70/-70
3063.178800 Series and 8800MELR Series Mortise Lock with or without Securitron EPTL Power Transfer Latching HardwareYesYes+60/-60
3063.188800 Series Mortise Locks, S8800 x Sym Series Mortise Locks (Latchbolt x Deadbolt engaged) Latching HardwareYesYes+70/-70
3063.198800 Series Mortise Locks, S8800 x Sym Series Mortise Locks (Latchbolt x Deadbolt engaged) Latching HardwareYesYes+115/-115
3063.208800 Series Mortise Lockset with or without Securitron MUNL Unlatch Electromechanical Strike Latching HardwareYesYes+60/-60

Standards cited

ASTM E1886 2005; ASTM E1996 2009; ASTM E330 2002; TAS 201, 202, 203 1994