FL Approval Watch
Florida product approvals: status, revisions, NOA expirations, weekly changes

Home / Windows / Pella Corporation

FL35284: Pella Corporation, Fixed

2026 code statusReady

FL35284-R4 is listed as Approved under code version 2026.

Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.

Filing record

2026 application
FL35284-R4, Approved (Revision) · state record
2023 code approval
FL35284-R3, Approved · state record
Submitted
Jul 17, 2026
Validated
Jul 18, 2026
Approved
Jul 21, 2026
Approved for HVHZ
No
Impact resistant
No
Compliance method
Certification Mark or Listing
Validated by
T.E. Lunn, PE, LLC

Products under this number (3)

#Model / descriptionHVHZImpactDesign pressure
35284.1Impervia Model 2 Fixed Casement Window 71.5" x 79.5" Non-Impact Fiberglass Fixed WindowNoNo+45/-45
35284.2Impervia Model 2 Fixed Casement Window 59.5" x 79.5" Non-Impact Fiberglass Fixed WindowNoNo+50/-50
35284.3Impervia Model 2 Fixed Casement Window 59.5" x 59.5" Non-Impact Fiberglass Fixed WindowNoNo+50/-60

Standards cited

AAMA/WDMA/CSA 101/I.S.2/A440 2011; AAMA/WDMA/CSA 101/I.S.2/A440 2017; ASTM E1886 2013; ASTM E1996 2017

Verify FL35284 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com

Other Pella Corporation numbers

All Pella Corporation FL numbers

Get the weekly list

New Florida approvals and filings, once a week. Unsubscribe any time.