FL Approval Watch
Florida product approvals: status, revisions, NOA expirations, weekly changes

Home / Exterior Doors / DKS Steel Door & Frames Systems,Inc

FL41130: DKS Steel Door & Frames Systems,Inc, Swinging Exterior Door Assemblies

2026 code statusPending

FL41130-R2 is on file under the 2026 code with status “Pending FBC Approval”. Not approved for 2026 yet.

Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.

Filing record

2026 application
FL41130-R2, Pending FBC Approval (Revision) · state record
2023 code approval
FL41130-R1, Approved · state record
Submitted
Oct 3, 2026
Validated
Oct 4, 2026
Pending FBC approval
Oct 9, 2026
Approved for HVHZ
Yes
Impact resistant
Yes
Compliance method
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Quality assurance
National Accreditation and Management Institute
Validated by
Ryan J. King, P.E.

Products under this number (8)

#Model / descriptionHVHZImpactDesign pressure
41130.1a. DKS Series 1800 Nominal 4'0 x 8'0 - 18 ga. Flush or Embossed Panel Commercial Steel Door in a 16 ga. Hollow Metal Steel Frame with 2" Head (Outswing Single Configuration "X")NoYesN/A
41130.2b. DKS Series 1800 Nominal 4'0 x 8'0 - 18 ga. Flush or Embossed Panel Commercial Steel Door in a 16 ga. Hollow Metal Steel Frame with 2" Head (Outswing Single Configuration "X")YesYesN/A
41130.3c. DKS Series 1800 Nominal 3'0 x 7'0 - 18 ga. Flush or Embossed Panel Commercial Steel Door (See INST drawing for Hardware Options) in a 16 ga. Hollow Metal Steel Frame with 2" or 4" Head (Outswing / Inswing Single Configuration "X")NoYesN/A
41130.4d. DKS Series 1800 Nominal 3'0 x 7'0 - 18 ga. Flush or Embossed Panel Commercial Steel Door (See INST drawing for Hardware Options) in a 16 ga. Hollow Metal Steel Frame with 2" or 4" Head (Outswing / Inswing Single Configuration "X")YesYesN/A
41130.5e. DKS Series 1800 Nominal 6'0 x 7'0 - 18 ga. Flush or Embossed Panel Commercial Steel Door (See INST drawing for Hardware Options) in a 16 ga. Hollow Metal Steel Frame with 2" or 4" Head (Outswing / Inswing Double Configuration "XX")NoYesN/A
41130.6f. DKS Series 1800 Nominal 6'0 x 7'0 - 18 ga. Flush or Embossed Panel Commercial Steel Door (See INST drawing for Hardware Options) in a 16 ga. Hollow Metal Steel Frame with 2" or 4" Head (Outswing / Inswing Double Configuration "XX")YesYesN/A
41130.7g. DKS Series 1800 Nominal 8'0 x 8'0 - 18 ga. Flush or Embossed Panel Commercial Steel Door (See INST drawing for Hardware Options) in a 16 ga. Hollow Metal Steel Frame with 2" Head (Outswing Double Configuration "XX")NoYesN/A
41130.8h. DKS Series 1800 Nominal 8'0 x 8'0 - 18 ga. Flush or Embossed Panel Commercial Steel Door (See INST drawing for Hardware Options) in a 16 ga. Hollow Metal Steel Frame with 2" Head (Outswing Double Configuration "XX")YesYesN/A

Standards cited

ASTM E1886 2005; ASTM E1996 2006; ASTM E330 2002; TAS 201 202 203 1994; UL 10C 2009

Verify FL41130 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com

Get the weekly list

New Florida approvals and filings, once a week. Unsubscribe any time.