Home / Roofing / The Metal Maniacs
FL46646: The Metal Maniacs, Metal Roofing
2026 code statusReady
FL46646-R1 is listed as Approved under code version 2026.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL46646-R1, Approved (Revision) · state record
- 2023 code approval
- FL46646, Approved · state record
- Submitted
- Jul 28, 2026
- Validated
- Aug 1, 2026
- Pending FBC approval
- Aug 4, 2026
- Approved
- Oct 13, 2026
- Approved for HVHZ
- Yes
- Impact resistant
- No
- Compliance method
- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
- Quality assurance
- Keystone Certifications, Inc.
- Validated by
- James R Wally, PE
Products under this number (8)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 46646.1 | 01: Aluminum 1.5" snaplock standing seam on plywood Nominally 0.032" or thicker aluminum 1.5" snaplock standing seam on 15/32" (min) plywood | Yes | N/A |
| 46646.2 | 02: Steel 1.5" snaplock standing seam on plywood 26ga (min) 1.5" snaplock standing seam on 15/32" (min) plywood | Yes | N/A |
| 46646.3 | 03: Steel 1.75" snaplock standing seam on plywood 24ga (min) 1.75" snaplock standing seam on 15/32" (min) plywood | Yes | N/A |
| 46646.4 | 04: Aluminum 1.75" snaplock standing seam on plywood Nominally 0.032" or thicker aluminum 1.75" snaplock standing seam on 15/32" (min) plywood | Yes | N/A |
| 46646.5 | 05: Steel 1.75" snaplock standing seam on plywood 24ga (min) 1.75" snaplock standing seam on 15/32" (min) plywood | No | N/A |
| 46646.6 | 06: Aluminum 1.75" snaplock standing seam on plywood Nominally 0.032" or thicker aluminum 1.75" snaplock standing seam on 15/32" (min) plywood | No | N/A |
| 46646.7 | 07: Aluminum 1.75" snaplock standing seam on steel deck Nominally 0.032" or thicker aluminum 1.75" snaplock standing seam on 22ga (min) steel deck | Yes | N/A |
| 46646.8 | 08: Steel 1.75" snaplock standing seam on steel deck 24ga 1.75" snaplock standing seam on 22ga (min) steel deck | Yes | N/A |
Standards cited
TAS 100 2023; TAS 125 2003; UL 580 2006