FL Approval Watch
Florida product approvals: status, revisions, NOA expirations, weekly changes

Home / Roofing / Sentry Metals

FL48047: Sentry Metals, Metal Roofing

2026 code statusReady

FL48047-R1 is listed as Approved under code version 2026.

Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.

Filing record

2026 application
FL48047-R1, Approved (Revision) · state record
2023 code approval
FL48047, Approved · state record
Submitted
Aug 17, 2026
Validated
Aug 19, 2026
Pending FBC approval
Aug 25, 2026
Approved
Oct 13, 2026
Approved for HVHZ
No
Impact resistant
No
Compliance method
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Quality assurance
Keystone Certifications, Inc.
Validated by
James R Wally, PE

Products under this number (5)

#Model / descriptionHVHZImpactDesign pressure
48047.101: 24ga 1.5" Snaplock 24ga (min) 1.5" clip-anchored snaplock standing metal roof panel on 15/32" (min) plywoodNoN/A+N/A/-123.5
48047.202: 032 Aluminum 1.5" Snaplock Nominally 0.032" aluminum (or thicker) 1.5" clip-anchored snaplock standing metal roof panel on 15/32" (min) plywoodNoN/A+N/A/-116
48047.303: 24ga 1" Nailstrip 24ga (min) 1" nailstrip standing metal roof panel on 15/32" (min) plywoodNoN/A+N/A/-146
48047.404: 032 Aluminum 1" Nailstrip Nominally 0.032" aluminum (or thicker) 1" nailstrip standing metal roof panel on 15/32" (min) plywoodNoN/A+N/A/-123.5
48047.505: 26ga 5V on plywood 26ga (min) 5V exposed fastener metal roof panel on 15/32" (min) plywoodNoN/A+N/A/-101

Standards cited

TAS 125 2003; UL 580 2006

Verify FL48047 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com

Get the weekly list

New Florida approvals and filings, once a week. Unsubscribe any time.