Home / Roofing / POLYGLASS USA
FL48189: POLYGLASS USA, Single Ply Roof Systems
2026 code statusReady
FL48189-R1 is listed as Approved under code version 2026.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL48189-R1, Approved (Revision) · state record
- 2023 code approval
- FL48189, Approved · state record
- Submitted
- Aug 6, 2026
- Validated
- Aug 6, 2026
- Approved
- Aug 7, 2026
- Approved for HVHZ
- Yes
- Impact resistant
- No
- Compliance method
- Evaluation Report from a Product Evaluation Entity Evaluation Entity NEMO CERT, LLC (Eval)
- Quality assurance
- NEMO CERT, LLC
- Validated by
- NEMO CERT, LLC (Validation)
Products under this number (2)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 48189.1 | Mapeplan PVC, Mapeplan PVC FB, Mapeplan KEE, and Mapeplan KEE FB Roof Systems Thermoplastic membrane roof systems | Yes | N/A |
| 4.3 | for all assemblies and max design pressures. 2.) Refer to NER Section 4 for |
Standards cited
ASTM D4434 2021; FM 4470 2022; FM 4474 2020; TAS 114 2011; UL 1897 2015; UL 790 2004
Miami-Dade NOAs, same maker
Matched by company name. The state doesn't link NOAs to FL numbers.
| NOA | Description | Expires |
|---|---|---|
| 26-0318.01 | Polyglass Acrylic CoatingsUnselected / Unknown, +0/−0 psf | July 30 2030 |
| 26-0318.02 | Polyglass BUR and Modified Roofing MembranesUnselected / Unknown, +0/−0 psf | April 23 2031 |
| 26-0622.02 | Polyglass Mastics, Flashings and Field Applied CoatingsUnselected / Unknown, +0/−0 psf | August 13 2031 |
| 21-1001.01 | Polyglass PMMA ResinUnselected / Unknown, +0/−0 psf | June 22 2028 |
| 21-1118.04 | Foam Systems over Wood Decks.Unselected / Unknown, +0/−97.5 psf | May 31 2027 |
| 22-0630.03 | Polyglass Roof Edge Termination SystemsUnselected / Unknown, +0/−0 psf | December 11 2028 |
| 22-0706.08 | Polyglass Modified Bitumen Roofing System Over Wood DecksUnselected / Unknown, +0/−120 psf | September 13 2027 |
| 22-0706.09 | Polyglass Self-Adhered Roof Systems over Wood DeckUnselected / Unknown, +0/−112.5 psf | October 11 2027 |
Verify FL48189 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com
Other POLYGLASS USA numbers
- FL1654 Not yetModified Bitumen Roof System
- FL5259 Not yetUnderlayments
- FL10291 PendingCements-Adhesives-Coatings
- FL16187 PendingLiquid Applied Roof Systems
- FL42093 ReadyWaterproofing
- FL46426 Not yetUnderlayments
- FL47068 ReadyWaterproofing
- FL47498 Not yetSpray Applied Polyurethane Roof System
- FL47534 PendingWaterproofing
Get the weekly list
New Florida approvals and filings, once a week. Unsubscribe any time.