Home / Structural Components / Bigbee Steel Buildings
FL7413: Bigbee Steel Buildings, Roof Deck
2026 code statusReady
FL7413-R8 is listed as Approved under code version 2026.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL7413-R8, Approved (Revision) · state record
- 2023 code approval
- FL7413-R7, Approved · state record
- Submitted
- Aug 14, 2026
- Validated
- Aug 18, 2026
- Pending FBC approval
- Aug 26, 2026
- Approved
- Oct 13, 2026
- Approved for HVHZ
- No
- Impact resistant
- No
- Compliance method
- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
- Quality assurance
- Farabaugh Engineering and Testing, LLC
- Validated by
- Steven M. Urich, PE
Products under this number (4)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 7413.1 | 24 Ga. Bigbee Rib II Roof 24 Ga. Bigbee Rib II Roof Panel over Open Framing | No | No |
| 7413.2 | 26 Ga. Bigbee Rib II Roof 26 Ga. Bigbee Rib II Roof Panel over Open Framing | No | No |
| 7413.3 | Bigbee VR-216 & VR-218 Roof Bigbee VR-216 & VR-218 Roof Panel over Open Framing | No | No |
| 7413.4 | BigbeeLok-324 Roof BigbeeLok-324 Roof Panel over Open Framing | No | No |
Standards cited
ASTM E 1592 2005; FM 4471 1992
Verify FL7413 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com
Other Bigbee Steel Buildings numbers
- FL7412 ReadyStructural Wall
Get the weekly list
New Florida approvals and filings, once a week. Unsubscribe any time.