Home / Structural Components / Berridge Manufacturing Co.
FL14210: Berridge Manufacturing Co., Roof Deck
2026 code statusReady
FL14210-R8 is listed as Approved under code version 2026.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL14210-R8, Approved (Revision) · state record
- 2023 code approval
- FL14210-R7, Approved · state record
- Submitted
- Aug 18, 2026
- Validated
- Aug 18, 2026
- Pending FBC approval
- Aug 26, 2026
- Approved
- Oct 13, 2026
- Approved for HVHZ
- No
- Impact resistant
- No
- Compliance method
- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
- Quality assurance
- UL LLC
- Validated by
- Steven M. Urich, PE
Products under this number (9)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 14210.1 | 1 - "Cee-Lock" Panel Snap-Lock, Structural Roof Panel 24 Ga. Steel, restrained by continuous “Cee-Rib” panel clips, attached to steel purlins | No | No |
| 14210.2 | 2 - "Cee-Lock" Panel Snap-Lock, Structural Roof Panel 22 Ga. Steel, restrained by continuous “Cee-Rib” panel clips, attached to steel purlins | No | No |
| 14210.3 | 3 - "Zee-Lock" Panel Standing Seam, Structural Roof Panel 24 Ga. Steel, restrained by continuous “Zee-Rib” panel clips or "Zee Clip" slider clips, mechanically seamed, attached to steel purlins | No | No |
| 14210.4 | 4 - "Double-Lock Zee-Lock" Panel Standing Seam, Structural Roof Panel 22 Ga. Steel, restrained by continuous “Zee-Rib” panel clips, mechanically seamed 180 degrees, attached to steel purlins | No | N/A |
| 14210.5 | 5 - "Deep Deck" Panel Lapped, Structural Roof Panel 24 Ga.or 22 Ga.Steel, attached to steel purlins | No | No |
| 14210.6 | 7 - "M-Panel" Lapped, Structural Roof Panel 26 Ga. or 24 Ga. Steel, attached to steel purlins | No | No |
| 14210.7 | 8 - "R-Panel" Lapped, Structural Roof Panel 26 Ga. or 24 Ga. Steel, attached to steel purlins | No | No |
| 14210.8 | 9 - "S-Deck" or "Curved S-Deck" Pane Lapped, Structural Roof Panel 24 Ga. Steel, attached to steel purlins | No | No |
| 14210.9 | 9- "Double-Lock Zee-Lock" Panel Standing Seam, Structural Roof Panel 22 Ga. Steel, restrained by continuous 3" “Zee-Rib” panel clips, mechanically seamed 180 degrees, attached to steel purlins | No | No |
Standards cited
ASTM E 1592 2017; TAS 125 2003; UL 1897 2015; UL 580 2006
Verify FL14210 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com
Other Berridge Manufacturing Co. numbers
- FL9000 ReadySoffits
- FL11159 ReadyMetal Roofing
- FL11241 Not yetMetal Roofing
- FL11269 ReadyMetal Roofing
- FL11422 ReadyMetal Roofing
- FL11462 ReadySiding
- FL14669 ReadyStructural Wall
- FL15471 ReadyMetal Roofing
- FL17025 ReadyMetal Roofing
- FL17437 ReadyStructural Wall
- FL18522 ReadyRoof Deck
- FL19999 ReadyMetal Roofing
Get the weekly list
New Florida approvals and filings, once a week. Unsubscribe any time.