Home / Roofing / Metal Alliance Inc.
FL29523: Metal Alliance Inc., Metal Roofing
2026 code statusPending
FL29523-R5 is on file under the 2026 code with status “Pending FBC Approval”. Not approved for 2026 yet.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL29523-R5, Pending FBC Approval (Revision) · state record
- 2023 code approval
- FL29523-R4, Approved · state record
- Submitted
- Sep 4, 2026
- Validated
- Sep 15, 2026
- Pending FBC approval
- Sep 20, 2026
- Approved for HVHZ
- Yes
- Impact resistant
- No
- Compliance method
- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
- Quality assurance
- Keystone Certifications, Inc.
- Validated by
- James R Wally, PE
Products under this number (10)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 29523.1 | 01: 100SL 1" Nailstrip 032 Aluminum 100SL 1" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
| 29523.2 | 02: 100SL 1" Nailstrip 24ga 100SL 1" Nailstrip panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
| 29523.3 | 03: 100SL 1" Nailstrip 26ga HVHZ 100SL 1" Nailstrip panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | Yes | N/A |
| 29523.4 | 04: 100SL 1" Nailstrip 032 Aluminum HVHZ 100SL 1" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | Yes | N/A |
| 29523.5 | 05: 150SL 1.5" Nailstrip 24ga 150SL 1.5" Nailstrip panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
| 29523.6 | 06: 150SL 1.5" Nailstrip 032 Aluminum 150SL 1.5" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
| 29523.7 | 07: 150SL 1.5" Nailstrip 032 Aluminum HVHZ 150SL 1.5" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | 19" coverage | Yes | N/A |
| 29523.8 | 08: 150SL 1.5" Nailstrip 24ga HVHZ 150SL 1.5" Nailstrip panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | 19" coverage | Yes | N/A |
| 29523.9 | 09: 100SL 1.0" Nailstrip 26ga 100SL 1" Nailstrip panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
| 29523.10 | 10: 100SL 1" Nailstrip 032 Aluminum 100SL 1" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
Standards cited
TAS 100 2023; TAS 125 2003; UL 580 2006
Verify FL29523 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com
Other Metal Alliance Inc. numbers
- FL30780 PendingMetal Roofing
- FL31652 PendingMetal Roofing
- FL31653 PendingMetal Roofing
- FL38752 PendingMetal Roofing
- FL39863 PendingStructural Wall
- FL45203 PendingMetal Roofing
- FL45918 PendingMetal Roofing
- FL45926 PendingMetal Roofing
- FL45927 PendingRoof Deck
- FL47732 PendingRoofing Accessories that are an Integral Part of the Roofing System
Get the weekly list