Home / Roofing / Metal Alliance Inc.
FL31652: Metal Alliance Inc., Metal Roofing
2026 code statusPending
FL31652-R5 is on file under the 2026 code with status “Pending FBC Approval”. Not approved for 2026 yet.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL31652-R5, Pending FBC Approval (Revision) · state record
- 2023 code approval
- FL31652-R4, Approved · state record
- Submitted
- Sep 11, 2026
- Validated
- Sep 19, 2026
- Pending FBC approval
- Sep 26, 2026
- Approved for HVHZ
- Yes
- Impact resistant
- No
- Compliance method
- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
- Quality assurance
- Keystone Certifications, Inc.
- Validated by
- James R Wally, PE
Products under this number (9)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 31652.1 | 01: 50ALLV 5V Crimp 26ga 50ALLV 5V Crimp panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | Yes | N/A |
| 31652.2 | 02: 50ALLV 5V Crimp 032 Aluminum 50ALLV 5V Crimp panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | Yes | N/A |
| 31652.3 | 03: 50ALLV 5V Crimp 26ga 50ALLV 5V Crimp panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
| 31652.4 | 04: 50ALLV 5V Crimp 032 Aluminum 50ALLV 5V Crimp panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
| 31652.5 | 05: 50ALLCOR Corrugated 26ga 50ALLCOR 0.75" Corrugated panels from 26ga(min) on 2x4 (nom) battens | No | N/A |
| 31652.6 | 06: 50ALLCOR Corrugated 26ga 50ALLCOR 0.75" Corrugated panels from 26ga(min) on 15/32" (min) plywood or 3/4" (min) wood plank | Yes | N/A |
| 31652.7 | 07: 50ALLRIB Rib 26ga 50ALLRIB Trapezoidal Rib panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
| 31652.8 | 08: 50ALLRIB Rib 26ga 50ALLRIB Trapezoidal Rib panel from 26ga (min) on 17/32" (min) OSB, plywood, or 3/4" (min) wood plank | No | N/A |
| 31652.9 | 09: 50ALLV 5V Crimp 26ga 50ALLV 5V Crimp panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | No | N/A |
Standards cited
TAS 100 2023; TAS 125 2003; UL 580 2006
Verify FL31652 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com
Other Metal Alliance Inc. numbers
- FL29523 PendingMetal Roofing
- FL30780 PendingMetal Roofing
- FL31653 PendingMetal Roofing
- FL38752 PendingMetal Roofing
- FL39863 PendingStructural Wall
- FL45203 PendingMetal Roofing
- FL45918 PendingMetal Roofing
- FL45926 PendingMetal Roofing
- FL45927 PendingRoof Deck
- FL47732 PendingRoofing Accessories that are an Integral Part of the Roofing System
Get the weekly list
New Florida approvals and filings, once a week. Unsubscribe any time.