Home / Structural Components / Cornerstone Building Brands (Fortify, ABC, Ceco, MBCI, Metal Sales, Metallic, Mueller, Robertson, Star, Union)
FL42382: Cornerstone Building Brands (Fortify, ABC, Ceco, MBCI, Metal Sales, Metallic, Mueller, Robertson, Star, Union), Roof Deck
2026 code statusPending
FL42382-R2 is on file under the 2026 code with status “Applied For”. Not approved for 2026 yet.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL42382-R2, Applied For (Revision) · state record
- 2023 code approval
- FL42382-R1, Approved · state record
- Submitted
- Oct 3, 2026
- Approved for HVHZ
- No
- Impact resistant
- No
- Compliance method
- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
- Quality assurance
- UL LLC
- Validated by
- James R Wally, PE
Products under this number (17)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 42382.1 | 01: Steel DoubleLok on purlins 24ga (min) DoubleLok on 16ga (min) purlins | No | N/A |
| 42382.2 | 02: Steel Mech Seam purlins 26ga or 24ga (min) Mech Seam on 16ga (min) purlins | No | N/A |
| 42382.3 | 03: Steel DoubleLok on purlins 24ga (min) DoubleLok on 16ga (min) purlins | No | N/A |
| 42382.4 | 04: Steel SuperLok on purlins 24ga or 22ga (min) SuperLok on 16ga (min) purlins | No | N/A |
| 42382.5 | 05: Steel Secure Seam on purlins 26ga (min) Secure Seam on 16ga (min) purlins | No | N/A |
| 42382.6 | 06: Steel LokSeam on purlins 24ga (min) LokSeam on 16ga (min) purlins | No | N/A |
| 42382.7 | 07: Steel Rib panel on purlins 29ga or 26ga (min) Rib panel on 18ga or 16ga (min) purlins | No | N/A |
| 42382.8 | 08: Steel Rib panel on wood purlins 29ga (min) Rib panel on 1x4 (min) wood purlins | No | N/A |
| 42382.9 | 09: Steel 5V on wood purlins 29ga (min) 5V panel on 1x4 (min) wood purlins | No | N/A |
| 42382.10 | 10: Steel Corrugated on purlins 26ga or 24ga (min) corrugated panel with nominal 7/8" rib height on 16ga (min) purlins | No | N/A |
| 7.2 | Panel on 16ga (min) purlins | No | N/A |
| 42382.12 | 12: Steel PBR on purlins 22ga-29ga PBR on 16ga (min) purlins | No | N/A |
| 42382.13 | 13: Steel PBU/M-Panel on purlins 26ga (min) PBR/M-Panel on 16ga (min) purlins | No | N/A |
| 42382.14 | 14: Steel UltraDek on purlins 24ga (min) UltraDek on 16ga (min) purlins | No | N/A |
| 42382.15 | 15: Steel TS 324 on purlins 24ga or 22ga (min) TS 324 on 16ga (min) purlins | No | N/A |
| 42382.16 | 16: Steel BattenLok HS on purlins 24ga (min) BattenLok HS on 16ga (min) purlins | No | N/A |
| 42382.17 | 17: Steel Retro-R on purlins 26ga (min) Retro-R on 16ga (min) purlins | No | N/A |
Standards cited
ASTM E1592 2017
Verify FL42382 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com