FL Approval Watch
Florida product approvals: status, revisions, NOA expirations, weekly changes

Home / Roofing / Cornerstone Building Brands (Fortify, ABC, Ceco, MBCI, Metal Sales, Metallic, Mueller, Robertson, Star, Union)

FL48220: Cornerstone Building Brands (Fortify, ABC, Ceco, MBCI, Metal Sales, Metallic, Mueller, Robertson, Star, Union), Metal Roofing

2026 code statusPending

FL48220-R1 is on file under the 2026 code with status “Applied For”. Not approved for 2026 yet.

Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.

Filing record

2026 application
FL48220-R1, Applied For (Revision) · state record
2023 code approval
FL48220, Approved · state record
Submitted
Oct 3, 2026
Approved for HVHZ
No
Impact resistant
No
Compliance method
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Quality assurance
UL LLC
Validated by
Yoosef Lavi, P.E.

Products under this number (11)

#Model / descriptionHVHZImpactDesign pressure
48220.15V-Crimp Min. 26 ga., 24 wide through fastened roof panel over min. 19/32” thick plywood deck with fasteners through panel flat.NoN/A+N/A/-149.6
48220.25V-Crimp Min. 26 ga., 24" wide through fastened roof panel over min. 15/32” thick plywood deck or 7/16" thick OSB with fasteners through panel rib.NoN/A+N/A/-214.3
48220.3Aluminum 5V-Crimp 24" wide, nom 0.032" thick aluminum through fastened roof panel over min 15/32” thick plywood deck or 7/16" thick OSB with fasteners through panel rib.NoN/A+N/A/-222.3
48220.4Aluminum Image II 16" wide, nom 0.032" thick aluminum concealed fastener roof panel over min 15/32” thick plywood deck or 7/16" thick OSB.NoN/A+N/A/-206
48220.5Aluminum Image II 16" wide, nom 0.032" thick aluminum concealed fastener roof panel over min 15/32” thick plywood deckNoN/A+N/A/-222.3
48220.6Aluminum Vertical Seam Nom. 0.032" thick, 16" wide, aluminum standing seam roof panel over min. 15/32” thick plywood deck or 7/16" thick OSB.NoN/A+N/A/-97.1
48220.7Aluminum Vertical Seam Nom. 0.032" thick, 16" wide, aluminum standing seam roof panel over min. 19/32” thick plywood deckNoN/A+N/A/-162
48220.8Image II 16" wide, min. 26 ga. concealed fastener roof panel over min. 15/32" thick plywood deckNoN/A+N/A/-222
48220.9Image II Min. 26 ga., 16" wide concealed fastened roof panel over min. 15/32” thick plywood deck or 7/16" thick OSB.NoN/A+N/A/-183.5
48220.10Vertical Seam Max. 16" wide, min. 24 ga. standing seam roof panel over min. 15/32" thick plywood deckNoN/A+N/A/-200
48220.11Vertical Seam Max. 18" wide, min. 24 ga. standing seam roof panel over min. 15/32" thick plywood deckNoN/A+N/A/-105

Standards cited

TAS 125 2003; UL 1897 2015; UL 580 2006

Verify FL48220 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com