FL15058: C.H.I. Overhead Doors, Sectional Exterior Door Assemblies
2026 code statusPending
FL15058-R8 is on file under the 2026 code with status “Validated”. Not approved for 2026 yet.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL15058-R8, Validated (Revision) · state record
- 2023 code approval
- FL15058-R7, Approved · state record
- Submitted
- Oct 16, 2026
- Validated
- Oct 16, 2026
- Approved for HVHZ
- No
- Impact resistant
- Yes
- Compliance method
- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
- Quality assurance
- Architectural Testing, Inc., an Intertek Company
- Validated by
- Kurt Dietrich PE
Products under this number (14)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 15058.01 | Rib Doors, Commercial Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 6'-00" through 8'-08" see drawing for applicable pressures. | No | No |
| 15058.02 | Rib Doors, Commercial Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 6'-00" through 10'-06" see drawing for applicable pressures. | No | No |
| 15058.03 | Rib Doors, Commercial Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 6'-00" through 10'-08" see drawing for applicable pressures. | No | Yes |
| 15058.04 | Rib Doors, Commercial Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 6'-00" through 12'-11" see drawing for applicable pressures. | No | No |
| 15058.05 | Rib Doors, Commercial Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 6'-00" through 10'-08" see drawing for applicable pressures. | No | Yes |
| 15058.06 | Rib Doors, Commercial Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 10'-02" through 14'-06" see drawing for applicable pressures. | No | Yes |
| 15058.07 | Rib Doors, Commercial Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 10'-06" through 18'-02" see drawing for applicable pressures. | No | No |
| 15058.08 | Rib Doors, Commercial Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 8'-02" through 20'-02" see drawing for applicable pressures. | No | No |
| 15058.09 | Rib Doors, Commercial Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 12'-02" through 16'-06" see drawing for applicable pressures. | No | No |
| 15058.10 | Rib Doors, Commercial Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 12'-02" through 24'-02" see drawing for applicable pressures. | No | No |
| 15058.11 | Rib Doors, Commercial Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 16'-02" through 24'-02" see drawing for applicable pressures. | No | Yes |
| 15058.12 | Rib Doors, Commercial Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 16'-08" through 28'-02" see drawing for applicable pressures. | No | No |
| 15058.13 | Rib Doors, Commercial Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 15'-02" through 20'-02" see drawing for applicable pressures. | No | Yes |
| 15058.14 | Rib Doors, Commercial Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 14'-02" through 22'-02" see drawing for applicable pressures. | No | No |
Standards cited
ANSI/DASMA 108 2017; ANSI/DASMA 115 2017
Verify FL15058 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com
Other C.H.I. Overhead Doors numbers
- FL10408 PendingSectional Exterior Door Assemblies
- FL12065 PendingSectional Exterior Door Assemblies
- FL15012 PendingSectional Exterior Door Assemblies
- FL15043 PendingSectional Exterior Door Assemblies
- FL15074 PendingSectional Exterior Door Assemblies
- FL16991 PendingRoll-Up Exterior Door Assemblies
- FL17096 PendingSectional Exterior Door Assemblies
Get the weekly list
New Florida approvals and filings, once a week. Unsubscribe any time.