Home / Exterior Doors / MidAmerica Door Dba GARAGA
FL24537: MidAmerica Door Dba GARAGA, Sectional Exterior Door Assemblies
2026 code statusPending
FL24537-R7 is on file under the 2026 code with status “Applied For”. Not approved for 2026 yet.
Last checked against floridabuilding.org: Oct 19, 2026, 11:30 AM ET. See the state record.
Filing record
- 2026 application
- FL24537-R7, Applied For (Revision) · state record
- 2023 code approval
- FL24537-R6, Approved · state record
- Submitted
- Oct 19, 2026
- Approved for HVHZ
- No
- Impact resistant
- No
- Compliance method
- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
- Quality assurance
- Architectural Testing, Inc., an Intertek Company
- Validated by
- Kurt Dietrich PE
Products under this number (20)
| # | Model / description | HVHZ | Impact |
|---|---|---|---|
| 24537.1 | EPS 2026V EPS 2026V 16x7 at a design pressure of +17.7/-19.7, Other sizes and pressures are available see drawing. | No | No |
| 24537.2 | EPS 2026V EPS 2026V 16x7 at a design pressure of +20.5/-22.8, Other sizes and pressures are available see drawing. | No | No |
| 24537.3 | EPS 2026V EPS 2026V 16x7 at a design pressure of +23.3/-26.0, Other sizes and pressures are available see drawing. | No | No |
| 24537.4 | EPS 2026V EPS 2026V 16x7 at a design pressure of +26.4/-29.4, Other sizes and pressures are available see drawing. | No | No |
| 24537.5 | EPS 2026V EPS 2026V 16x7 at a design pressure of +30.0/-33.5, Other sizes and pressures are available see drawing. | No | No |
| 24537.6 | EPS 2026V EPS 2026V 9x7 at a design pressure of +21.4/-24.1, Other sizes and pressures are available see drawing. | No | No |
| 24537.7 | EPS 2026V EPS 2026V 9x7 at a design pressure of +24.3/-27.5, Other sizes and pressures are available see drawing. | No | No |
| 24537.8 | EPS 2026V EPS 2026V 9x7 at a design pressure of +27.6/-31.2, Other sizes and pressures are available see drawing. | No | No |
| 24537.9 | EPS 2026V EPS 2026V 9x7 at a design pressure of +30.8/-34.8, Other sizes and pressures are available see drawing. | No | No |
| 24537.10 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 16x7 at a design pressure of +15.5/-17.2, Other sizes and pressures are available see drawing. | No | No |
| 24537.11 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 16x7 at a design pressure of +15.5/-17.2, Other sizes and pressures are available see drawing. | No | No |
| 24537.12 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 16x7 with a design pressure of +17.7/-19.7. Other sizes and pressures are available see drawing. | No | No |
| 24537.13 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 16x7 with a design pressure of +20.4/-22.7. Other sizes and pressures are available see drawing. | No | No |
| 24537.14 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 16x7 with a design pressure of +23.3/-26.0. Other sizes and pressures are available see drawing. | No | No |
| 24537.15 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 9x7 at a design pressure of +16.1/-18.2, Other sizes and pressures are available see drawing. | No | No |
| 24537.16 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 9x7 at a design pressure of +19.1/-22.0, Other sizes and pressures are available see drawing. | No | No |
| 24537.17 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 9x7 at a design pressure of +22.9/-26.3, Other sizes and pressures are available see drawing. | No | No |
| 24537.18 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 9x7 at a design pressure of +27.6/-31.2, Other sizes and pressures are available see drawing. | No | No |
| 24537.19 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 9x7 at a design pressure of +31.2/-35.8, Other sizes and pressures are available see drawing. | No | No |
| 24537.20 | OB 2025/2024, OBI 2025/2024 OB 2025/2024, OBI 2025/2024 16x7 at a design pressure of +26.4/-29.4, Other sizes and pressures are available see drawing. | No | No |
Standards cited
ANSI/DASMA 108 2017
Verify FL24537 on floridabuilding.org before you rely on it for a permit. Spot an error? info@flapprovalwatch.com
Other MidAmerica Door Dba GARAGA numbers
- FL48037 PendingSectional Exterior Door Assemblies